Frames | No Frames

Return to Stylus Studio EDIFACT home page.
Return to Stylus Studio EDIFACT D99B Segments page.

DGS -

Dangerous goods
UN/CEFACT Revision 1999B Segment List

Function:To identify dangerous goods.
This segment also occurs in the following versions of this standard:
D93A, D94A, D94B, D95A, D95B, D96A, D96B, D97A, D97B, D98A, D98B, D99A, D99B, D00A, D00B, D01A, D01B, D01C, D02A, D02B, D03A, D03B, D04A, D04B

Pos Segment M/C Repeat Repr. Notes
010 8273 Dangerous goods regulations code C 1 an..3
020 C205 HAZARD CODE C 1
8351 Hazard code identification M an..7
8078 Hazard substance/item/page number C an..7
8092 Hazard code version number C an..10
030 C234 UNDG INFORMATION C 1
7124 UNDG number C n4
7088 Dangerous goods flashpoint C an..8
040 C223 DANGEROUS GOODS SHIPMENT FLASHPOINT C 1
7106 Shipment flashpoint C n3
6411 Measurement unit code C an..3
050 8339 Packing group, coded C 1 an..3
060 8364 EMS number C 1 an..6
070 8410 MFAG C 1 an..4
080 8126 Trem card number C 1 an..10
090 C235 HAZARD IDENTIFICATION PLACARD DETAILS C 1
8158 Hazard identification number, upper part C an..4
8186 Substance identification number, lower part C an4
100 C236 DANGEROUS GOODS LABEL C 1
8246 Dangerous goods label marking C an..4
8246 Dangerous goods label marking C an..4
8246 Dangerous goods label marking C an..4
110 8255 Packing instruction, coded C 1 an..3
120 8325 Category of means of transport, coded C 1 an..3
130 8211 Permission for transport, coded C 1 an..3

PosPosition
M/CMandatory or Conditional
Repr.Representation (Data or Content Type)

Segment DGS is used in the following messages:
BAPLIECOARRICODECOCOPARNCOPINOCOPRARCOREORCOSTCO
COSTORCUSCARDESADVDGRECAHANMOVIFCSUMIFTCCAIFTDGN
IFTFCCIFTIAGIFTMANIFTMBCIFTMBFIFTMBPIFTMCAIFTMCS
IFTMINIFTSAIIFTSTAINVOICITRRPTMOVINSORDERSPRODAT
QUOTESRETANNRETINSSAFHAZWASDIS

Change indicators
plus sign An addition.
asterisk Addition/substraction/change to a code entry for a particular data element.
hash or pound sign Changes to names.
vertical bar Changes to text for descriptions, notes and functions.
minus sign A deletion.
letter X Marked for deletion.

Return to Stylus Studio EDIFACT D99B Segments page.
EDI to XML Mapping for EDIFACT/X12 Convert EDIFACT/X12 Schemas to XML Schema Legacy Data Conversion Tools Access Relational Data as XML Visual XSLT and XQuery Mapping Tools EDIFACT to XML
Return to Stylus Studio EDIFACT home page.

Return to Stylus Studio home page.
Site Map | Privacy Policy | Terms of Use | Trademarks
Stylus Scoop XML Newsletter:
W3C Member
Stylus Studio® and DataDirect XQuery ™are from DataDirect Technologies, is a registered trademark of Progress Software Corporation, in the U.S. and other countries. © 2004-2016 All Rights Reserved.