Frames | No Frames

Return to Stylus Studio EDIFACT home page.
Return to Stylus Studio EDIFACT 40100 Segments page.

USX -

Security references
UN/EDIFACT Syntax Version 4 Release 1 Segment List

Function:To refer to the secured EDIFACT structure and its associated date and time.
This segment also occurs in the following versions of this standard:
40000, 40100

Pos Segment M/C Repeat Repr. Notes
010 0020 Interchange control reference M 1 an..14
020 S002 INTERCHANGE SENDER C 1
0004 Interchange sender identification M an..35
0007 Identification code qualifier C an..4
0008 Interchange sender internal identification C an..35
0042 Interchange sender internal sub-identification C an..35
030 S003 INTERCHANGE RECIPIENT C 1
0010 Interchange recipient identification M an..35
0007 Identification code qualifier C an..4
0014 Interchange recipient internal identification C an..35
0046 Interchange recipient internal sub-identification C an..35
040 0048 Group reference number C 1 an..14
050 S006 APPLICATION SENDER IDENTIFICATION C 1
0040 Application sender identification M an..35
0007 Identification code qualifier C an..4
060 S007 APPLICATION RECIPIENT IDENTIFICATION C 1
0044 Application recipient identification M an..35
0007 Identification code qualifier C an..4
070 0062 Message reference number C 1 an..14
080 S009 MESSAGE IDENTIFIER C 1
0065 Message type M an..6
0052 Message version number M an..3
0054 Message release number M an..3
0051 Controlling agency, coded M an..3
0057 Association assigned code C an..6
0110 Code list directory version number C an..6
0113 Message type sub-function identification C an..6
090 0800 Package reference number C 1 an..35
100 S501 SECURITY DATE AND TIME C 1
0517 Date and time qualifier M an..3
0338 Event date C n..8
0314 Event time C an..15
0335 Language, coded C an..3

PosPosition
M/CMandatory or Conditional
Repr.Representation (Data or Content Type)
Dependency Notes:
1.D5(050, 040) If first, then all
2.D1(070, 090) One and only one
3.D5(060, 040) If first, then all
4.D5(080, 070) If first, then all

Segment USX is used in the following messages:
AUTACKKEYMAN

Change indicators
plus sign An addition.
asterisk Addition/substraction/change to a code entry for a particular data element.
hash or pound sign Changes to names.
vertical bar Changes to text for descriptions, notes and functions.
minus sign A deletion.
letter X Marked for deletion.

Return to Stylus Studio EDIFACT 40100 Segments page.
EDI to XML Mapping for EDIFACT/X12 Convert EDIFACT/X12 Schemas to XML Schema Legacy Data Conversion Tools Access Relational Data as XML Visual XSLT and XQuery Mapping Tools EDIFACT to XML
Return to Stylus Studio EDIFACT home page.

Return to Stylus Studio home page.
Site Map | Privacy Policy | Terms of Use | Trademarks
Stylus Scoop XML Newsletter:
W3C Member
Stylus Studio® and DataDirect XQuery ™are from DataDirect Technologies, is a registered trademark of Progress Software Corporation, in the U.S. and other countries. © 2004-2016 All Rights Reserved.